Know Issues PLUS+1™

PLUS+1 GUIDE Version 4.0.x known issues.

June 2008

When installing an older version of GUIDE, the program will not automatically uninstall the current version (4.x and later).

Work-around

The current version of GUIDE must be manually uninstalled. This is done by using Add/Remove Programs in the Windows Control Panel.

Solution

In the future this will enable a user to have multiple installations of different GUIDE versions

 

 

June 2008

Double spacing in project file names

Some issues have been found in projects where file names have double spaces. Single spaces in file names are not known to cause any problems.

Work-around

Only use single spaces in project file names.

Solution

For now only use single spaces in your project file names.

 

June 2008

Components without output types (e.g. Hardware Input) cannot be directly connected to a class instance

This will generate a compile error

Work-around

Use a retype connection in between.

Solution

 

June 2008

Autotyped constants will not work when connected directly to Objects

This will generate a compile error.

Work-around

Use a Typed constant

Solution

 

June 2008

The linked page feature must not be used with older HWDs

Work-around

Update to a newer HWD file.

Solution

For each released HWD, the table below lists the versions that do not work:

MC24-10: 10101528v150 and older
MC24-20: 10102117v120 and older
MC50-10: 10101674v150 and older
MC50-20: 10102569v110 and older
DP600: 10102102B and older
DP610: 10102903B and older